Installing Cards
36
◆
Installation
DSX-80/160 Hardware Manual
Connecting 16COIU and 8COIU Cards
The COIU Card, just like the SLI and16ESIU Cards, uses 8-pin mod jacks to connect extensions. Using the
Installation Cable (P/N 808920) makes it easy to connect the cards to standard 66M1-50 connecting blocks.
These cables have six 8-pin modular jacks on one end and are unterminated on the other. Each jack connects
four lines. At minimum, the installation site needs:
❥
One 66M1-50 block and Installation Cable (P/N 808920) for extensions and optional equipment.
❥
One 66M1-50 block and Installation Cable (P/N 808920) for analog lines.
❥
Depending on your card con
fi
guration and local codes, you may need an additional 66M1-50 block and
Installation Cable (P/N 808920) for optional equipment.
To punch down the cables:
For each 66M1-50 block, punch down the Installation Cable in standard color-code order.
Figure 18: Connecting 16COIU and 8COIU Cards
4 Slot Cabinet
shown
WHT-BLU
BLU-WHT
WHT-ORN
ORN-WHT
WHT-GRN
GRN-WHT
WHT-BRN
BRN-WHT
WHT-SLT
SLT-WHT
RED-BLU
BLU-RED
RED-ORN
ORN-RED
RED-GRN
GRN-RED
RED-BRN
BRN-RED
RED-SLT
SLT-RED
BLK-BLU
BLU-BLK
BLK-ORN
ORN-BLK
BLK-GRN
GRN-BLK
BLK-BRN
BRN-BLK
BLK-SLT
SLT-BLK
YEL-BLU
BLU-YEL
YEL-ORN
ORN-YEL
YEL-GRN
GRN-YEL
YEL-BRN
BRN-YEL
YEL-SLT
SLT-YEL
VIO-BLU
BLU-VIO
VIO-ORN
ORN-VIO
VIO-GRN
GRN-VIO
VIO-BRN
BRN-VIO
VIO-SLT
SLT-VIO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
5
4
3
6
2
7
1
8
5
4
3
6
2
7
1
8
5
4
3
6
2
7
1
8
5
4
3
6
2
7
1
8
5
4
3
6
2
7
1
8
5
4
3
6
2
7
1
8
1 T
1 R
2 T
2 R
3 T
3 R
4 T
4 R
5 T
5 R
6 T
6 R
7 T
7 R
8 T
8 R
9 T
9 R
10 T
10 R
11 T
11 R
12 T
12 R
13 T
13 R
14 T
14 R
15 T
15 R
16 T
16 R
BLOCK
TERM
25-PAIR CABLE
COLOR
CODE
FUNCTION
RJ61X
RJ61X
1
2
3
4
1093096 - 19
Lines 1-16
NC
PCB Location
1
8
RJ61X Plug
16COIU PCB
1
3 4
2
To make your own cables, see
Making
Your Own Cables
(page 39).
DSX-80 4-Slot KSU Shown