System Configuration
20
◆
Components
DSX Product Description
DSX-80/160 System Load Factor Worksheet
Description
Qty
Load Type
5 VDC
40 VDC
Load
Total
Load
Total
CPU Card
1
12
12
0
0
16ESIU Card
8
20
8SLIU Card
5
8
16SLIU Card
10
16
8COIU Card
3
0
16COIU Card
6
0
T1/E1/PRI Card
8
0
Item 1: Load Type Totals
(Cannot exceed Item 2: Power Supply Capacity.)
Item 2: Power Supply Capacity
If you have one power supply installed, the capacity is:
If you have two power supplies installed, the capacity is:
If you have three power supplies installed, the capacity is:
5 VDC = 40
5 VDC = 80
5 VDC = 120
40 VDC = 48
40 VDC = 80
40 VDC = 120
Notes:
•
DSX-80 can only have 1 power supply.
•
DSX-160 can have up to 3 power supplies. You
cannot
have more than two 16ESIU Cards per power supply,
regardless of System Load Factor calculations.
•
Exceeding the allowed Load Type Total (Item 1) will cause the system’s power supplies to automatically shut down
and/or cause erratic system operation.
•
The total of all station, line, DSS Console, and voice mail ports cannot exceed 160.
Summary of Contents for DSX PRODUCT DESCRIPTION
Page 150: ...138 IntraMail Features DSX Product Description...
Page 160: ...Parts List 148 Specifications and Parts DSX Product Description...
Page 161: ......