Troubleshooting 6-11
Messages displayed on lower line
When STATUS lamp is off:
On-screen
message
Description
Action
SMI Timeout
A timeout error
occurred during
system management
interrupt.
1. Take one of the following measures to reboot (reset)
the maintenance card.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC ESMPRO
Manager.
2. Take one of the following measures to power off the
maintenance card and then on.
* Press the Maintenance switch to power off the
maintenance card, then press it again to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC ESMPRO
Manager.
3. Power off the maintenance card by pressing the
POWER switch of EcoPowerGateway, then turn it on.
4. If the same error persists, contact your service
representative.
WDT Timeout
Watchdog timer
timeout error
occurred.
1. Take one of the following measures to reboot (reset)
the maintenance card.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC ESMPRO
Manager.
2. Take one of the following measures to power off the
maintenance card and then on.
* Press the Maintenance switch to power off the
maintenance card, then press it again to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC ESMPRO
Manager.
3. Power off the maintenance card by pressing the
POWER switch of EcoPowerGateway, then turn it on.
4. If the same error persists, contact your service
representative.
Processor T-
Trip
Forced power-off
occurred due to a
thermal error in
processor.
1. Check if dust or stain is adhered to the fan of the
power unit or not.
2. Check if blank cover is surely installed in the slot
which does not contain any power unit.
3. Check the ambient temperature of installation
location.
4. Take one of the following measures to reboot (reset)
the maintenance card.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC ESMPRO
Manager.
Summary of Contents for EcoPowerGateway N8142-36F
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ... This page is intentionally left blank ...
Page 16: ...vi This page is intentionally left blank ...
Page 21: ...Notes on Using Your EcoPowerGateway 1 5 ...
Page 23: ...Notes on Using Your EcoPowerGateway 1 7 ...
Page 26: ...1 10 Notes on Using Your EcoPowerGateway ...
Page 29: ...Notes on Using Your EcoPowerGateway 1 13 ...
Page 38: ...1 22 Notes on Using Your EcoPowerGateway This page is intentionally left blank ...
Page 56: ...2 18 General Description This page is intentionally left blank ...
Page 136: ...A 2 Specifications This page is intentionally left blank ...