___________________________________________________________________________________
6 - 176
Installing ETUs (Circuit Cards)
___________________________________________________________________________________
Document Revision 3
Electra Elite IPK II
8.10.2
License
Version 1500 or higher – 4-port license registration provides users
with the flexibility of adding CCISoIP ports in increments of four (4, 8,
12, 16, 20 and 24) or (MG16) DSP resources in increments of four
(4, 8, 12 and 16).
Version 1500 or higher - 16-port Conference License registration
provides users with the flexibility of adding 16 Conference ports.
Version 2000 or higher – Using the MG_CCIS Combo Package
4-port license registration provides users with the flexibility of adding
CCISoIP ports in increments of four (4, 8, 12, 16, 20 and 24) or
(MG16) DSP resources in increments of four (4, 8, 12, 16, 20 and
24).
8.10.3
Installation
Basic Port Package
Each PVA(X)-U( ) ETU installed with the MG16 Package
counts for up to 16 TDM Talk Paths [2 PVA(X)-U( ) ETUs
max].
Each PVA(X)-U( ) ETU installed with the CCISoIP Package
counts for up to 24 Trunk Ports of the 64 Total Ports [2
PVA(X)-U( ) ETUs max].
Each PVA(X)-U( ) ETU installed with the CNF Package counts
for up to 16 Extension ports of the 64 Total Ports (1 Conference
ETU max).
Each PVA(X)-U( ) ETU installed with the MG_CCIS Package
counts for up to 24 Trunk Ports of the 64 Total Ports and up to
24 TDM Talk Paths [2 PVA(X)-U( ) ETUs max].
Expanded Port Package
Each PVA(X)-U( ) ETU installed with the MG16 Package
counts for up to 16 TDM Talk Paths [13 PVA(X)-U( ) ETUs
max per system].
Each PVA(X)-U( ) ETU installed with the CCISoIP Package
counts for up to 24 Trunk Ports* of the max 200 Trunk Ports [11
PVA(X)-U( ) ETUs max per system].
Each PVA(X)-U( ) ETU installed with the CNF Package counts
for up to 16 Extension ports of the max 256 Extension Ports (1
Conference ETU max per system).
Each PVA(X)-U( ) ETU installed with the MG_CCIS Package
counts for up to 24 Trunk Ports* of the max 200 Trunk Ports
and up to 24 TDM Talk Paths [23 PVA(X)-U( ) ETUs max per
system].
* The system has a maximum of four 24-port ETUs (T-1, PRI,
PVA with CCISoIP, PVA with MG_CCIS).