___________________________________________________________________________________
14 - 20
System Maintenance
___________________________________________________________________________________
Document Revision 3
Electra Elite IPK II
G1
External Paging Problems
Yes
Yes
Yes
No
No
No
Install amplifier.
Amplifier
provided?
Place Test Set on output of paging
at KSU port or PDG(2)-U10 ADP
with all external wiring removed.
External
page heard on
test set?
External amplifier or PRG
11-01 and 11-10~11-15
Check PRG 11-01 and 11-10~11-15
for correct access code (external) for
paging.
Done.
Pass
Fail
Retest using
correct access
code.
Access Code
correct?
1. Reset/replace PDG(2)-U10 ADP, and test.
2. Perform Second Initialization, and test; then
perform First Initialization and test.
3. Replace CPUII( )-U( ) ETU, and test
using default program.
Summary of Contents for ELECTRA ELITE IPK II