Program 20 : System Option Setup
Description
Use Program 20-25 : ISDN Options to define the ISDN system options.
Program 20 : System Option Setup
20-25 : ISDN Options
Level:
IN
Input Data
Item
No.
Item
Input Data
Default
01
Send the Release Message After Subscriber Hangs
Up
0
= Service Off
1
= Service On
1
02
Progress Indicate Information Element Detect
0
= Service Off
1
= Service On
1
03
Bearer Capability Select from SLT Outgoing
0
= 3.1KHz Audio
1
= Speech
0
04
Send DT until user dials first digit (Local Dial Tone)
With Overlap Sending Mode, if the network side stops
dial tone when CLI is included in the SETUP message,
the system sends dial tone until the user dials the first
digit instead of the network.
0
= Service Off
1
= Service On
0
05
T305 Timer Start After Sending Disconnect
Message
0
= Service Off
1
= Service On
1
06
Call Proceeding Send Mode
0
= Service Off
1
= Service On
1
07
Local Busy Tone Mode Set When Disconnect
Message Received
0
= Local Busy Tone
Off
1
= Busy Tone from
NT (network side)
0
08
Use of Low Layer Compatibility (LLC)
0 = Disable (Off)
1 = Enable (On)
1
09
Use of High Layer Compatibility (HLC) Sending
0 = Disable (Off)
1 = Enable (On)
1
10
S-Point Terminal Seizes Analog Trunk
0 = Disable (Off)
1 = Enable (On)
1
11
Automatic Changing System Clock When Date/
Time Information Element Received
0 = Disable (Off)
1 = Enable (On)
0