Electra Elite IPK II
Document Revision 1
Electra Elite IPK II Programming Manual
2 - 227
Description
Use Program 22-02 : Incoming Call Trunk Setup to assign the incoming trunk type
for each trunk. There is one item for each Night Service Mode.
Conditions
H
When connecting to T1 trunks, after changing Program 22-02-01 to match the
Telco’s connected T1 service type, the T1 cable or the T1 PCB must be
unplugged and then reconnected in order for the T1 PCB to sync.
H
When the trunk type is set to a 3 (DID), the DID Transfert Destination in 22-11-04
for each DID feature is not supported. This feature is only supported for DID
trunks when assigned as VRS.
Feature Cross Reference
J
Central Office Calls, Answering
Program 22 : Incoming Call Setup
22-02 : Incoming Call Trunk Setup
Level:
IN
Input Data
Trunk Port Number
001~200
Item
No.
Day/Night
Mode
Incoming Type
Default
Description
Related
Program
01
1~8
0
= Normal
1
= VRS (second
dial tone if no
VRS installed)
2
= DISA
3
= DID
4
= DIL
5
= E&M Tie line
6
= Delayed VRS
7
= ANI/DNIS
8
= DID(DDI) Mode
Switching
0
Use this option to set the
feature type for the trunk
you are programming.
14-04