Electra Elite IPK II
Document Revision 1
Electra Elite IPK II Programming Manual
2 - 495
Description
Use Program 81-10 : COI Initial Data Setup to define the various basic timers for
each COI trunk port.
Program 81 : Basic Hardware Setup for Trunk
81-10 : COI Initial Data Setup
Level:
IN
Input Data
Trunk No.
1~ 200
Item
No.
Item
Input Data
Default
01
DP Interdigit Time Selection
The DP Interdigit Time is the minimum
pause time between dial pulses. Use this
Program to select either Pattern A or pattern
B.
0 = Pattern A
(Pattern A: 10pps - 650 ms,
20pps - 500 ms)
1 = Pattern B
(Pattern B: 10pps - 800 ms,
20pps - 800 ms)
1
02
Prepause Time Selection
Specifies the loop open time for a hookflash
signal sent to the CO or PBX when the
Recall key on a multiline terminal is
pressed. A Single Line Telephone (SLT)
generates a hookflash to the CO or PBX
line when a SLT hookflash is assigned.
1~13
(1~13 seconds)
(0 = No Setting)
9
(600 ms)
03
Incoming Signal Detect Time Selection
Specifies the time after the incoming signal
from another system is detected before the
acknowledge signal is sent out.
0~15
(50~800 ms)
3
(200 ms)
04
Disconnect Recognition Time Selection
Specifies the minimum time before a
disconnected circuit can be accessed
again.
1~15
(100 ms~1.5 seconds)
(0 = No Setting)
3
(300 ms)
05
Auto Release Signal Detection Time
Specifies the signal detection time for
release of a CO/PBX line after a disconnect
signal is received from the distant CO or
PBX.
1~14
(50~700 ms)
15 =
∞
(0 = No Setting)
7
(350 ms)
06
Pause Time Selection
1~15
(500~7500 ms)
3
(200 ms)
Summary of Contents for ELECTRA ELITE IPK II
Page 2: ...PROGRAMMING MANUAL INT 1073 IPK II DOCUMENT REVISION 1 RELEASE 1000...
Page 3: ......
Page 5: ......
Page 7: ......
Page 616: ......
Page 617: ...PROGRAMMING MANUAL NEC Unified Solutions Inc Document Revision 1...