___________________________________________________________________________________
6 - 166
Installing ETUs (Circuit Cards)
___________________________________________________________________________________
Document Revision 3
Electra Elite IPK II
8.7.2
Installation
The HUB(8)-U( ) ETU cannot be installed in a KSU that contains an
EliteMail VP or CTI system.
This ETU has an attached green cable that must be connected to
frame ground.
Basic Port Package
Only one HUB(8)-U( ) ETU can be installed in slots S1~S8.
The system is limited by 64 trunk and station ports combined. This
ETU shares the total number of station ports in the system.
Expanded Port Package
Only one HUB(8)-U( ) ETU can be installed in slots S1~S8.
The system is limited by 256 stations. This ETU shares the total
number of station ports in the system.
8.7.3
Switch Settings
Press switch SW1 to Reset the HUB(8)-U( ) ETU.
8.7.4
LED Indications
Refer to
8.7.5
Connectors
The following connectors are included:
J
CN1
Connects to the backplane.
J
CN3
Three pin Jumper. Pins 2 and 3 are shorted for
Normal operation.
J
CN5
Channel 1~4 RJ45C Connectors
J
CN6
Channel 5~8 RJ45C Connectors
Table 6-61 HUB(8)-U( ) LEDS
LED
ON
OFF
Blinking
LED1
No Power to ETU
Normal Operation
RJ45C Yellow
100 Mbps
10 Mbps
N/A
RJ45C Green
LINK
No Link
Data Tx/Rx