The PVA(X)-U( ) ETU has the following switches.
J
DIP switch SW1
Table 6-70 PVA(X)-U( ) ETU Rotary Switch SW3
. This
switch has four selector switches:
H
SW1-1
N/A
H
SW1-2
N/A
H
SW1-3
N/A
H
SW1-4
Placed ON to restore factory default software
package when used with Rotary Switch SW3.
H
RESET Switch SW2
This switch allows the technician to reset the PVA(X)-U( )
without having to remove and insert it again in the KTS.Rotary
Switch SW3
This 16-position (0~9,A~F) rotary switch selects display
options. Only A is currently used. Refer to
PVA(X)-U( ) ETU Rotary Switch SW3
8.10.6
LED Indications
Refer to
Table 6-71 Default Boot Sequence: In Active PVA(X)-U( )
ETU without IP Application Loaded
.
The Boot sequence in this table occurs when the ETU is at factory
default and the IP Application is not loaded.
Refer to
Table 6-72 Active PVA(X)-U( ) ETU with IP Application
.
Table 6-70 PVA(X)-U( ) ETU Rotary Switch SW3
SW1-4
Setting
SW3
Position
Status
ON
A
Restores Factory Default Package
Notes:
1.
When setting factory configuration, the ETU must initially boot up
with configured switch settings.
2.
When Rotary Switch SW3 is selected, Switch SW1-4 must be ON.
3. Restoring the factory software package may take up to five
minutes.
4.
When the ETU has completed booting, return Switch SW1-4 to
OFF and Rotary Switch SW3 to 0.