Electra Elite IPK II
Document Revision 3
System Hardware Manual
9 - 15
___________________________________________________________________________________
___________________________________________________________________________________
3.3.1
Switch Settings
The AP(A)-R Unit and AP(R)-R Unit have three switch locations.
Refer to
Table 9-3 AP(A)-R/AP(R)-R Unit Switch Settings
for a
description of each switch and an explanation of the settings.
Figure 9-16 AP(A)-R Unit/AP(R)-R Unit Switches
Table 9-3 AP(A)-R/AP(R)-R Unit Switch Settings
Switch
Description/Settings
SW1
SW1-1
Connects to Multiline Terminal (Default).
SW1-2
Not Used
SW3
SW3-1
Sets impedance to 600
Ω
for devices such as
modems or facsimile machines.
SW3-2
Used for complex impedance devices such as
Single Line Telephones.
Dip
Switch
es
(DSW)
DSW
1~8
Leave switches at default.