11 - 6
Installing Electra Elite Optional Terminal Equipment
___________________________________________________________________________________
Document Revision 3
Electra Elite IPK II
S
ECTION
3
I
NSTALLATION
P
ROCEDURES
3.1
ACA-U Unit (AC Adapter)
This unit provides power to ancillary devices, Attendant Consoles, or the
DTP-16HC-1 TEL. Except for the DTP-16HC-1 TEL, the ACA-U Unit connects
to one of the following adapters installed on a Multiline Terminal: APR-U Unit,
CTA-U Unit, CTU(S)-U Unit or HFU-U Unit. When more than one adapter is
installed on a Multiline Terminal, only one ACA-U Unit is necessary.
The power requirements for the ACA-U Unit are:
J
Input: 120 Vac, 60 Hz, 30W
J
Output: 24 Vdc, 750 mA
J
Polarity:
3.1.1
Connecting the ACA-U Unit
1.
Unplug the line cord from the Multiline Terminal and unplug the
ACA-U Unit from the AC outlet.
2.
Prepare Multiline Terminal for adapter installation. Refer to
Section 2 Preparing Multiline Terminal for Adapter Installation
.
3.
Locate the AC Adapter plug on the ancillary device that is
connected to the bottom of the Multiline Terminal and plug in
the AC Adapter.
⊕
Failing to do this can damage the unit and/or the
Multiline Terminal.