2 - 124
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Elite IPK
1-3-06
Hookflash End Time Selection
General Description
Use this Memory Block to specify the maximum hookflash duration from a Single Line
Telephone to receive a second dial tone.
Display
Settings
Page 1
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is
the default.
HST =
Hookflash
Start Time
00
(HST + 0 ms.)
01
(HST + 100 ms.)
02
(HST + 200 ms.)
03
(HST + 300 ms.)
04
(HST + 400 ms.)
05
(HST + 500 ms.)
06
(HST + 600 ms.)
07
(HST + 700 ms.).
Page 2
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
08
(HST + 800 ms.)
09
(HST + 900 ms.)
10
(HST + 1000 ms.)
11
(HST + 1100 ms.)
12
(HST + 1200 ms.)
13
(HST + 1300 ms.)
14
(HST + 1400 ms.)
15
(HST + 1500 ms.)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 +
KF
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Press
C
to cycle between pages.
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-3-05
Hookflash Start Time Selection
System Mode
1
Submode
3
Data No.
06
PC Programming
¦
+BTI
0 6 : F L S H
E N D = 0 7 | 1
T I M E
D I S P L A Y
Data
No.
Title
Page
No.
Setting
Data
Summary of Contents for ElectraElite IPK