Automated Attendant PBR Timeout
Response Selection
General Description
Use this Memory Block to specify how a call answered by the Automated Attendant
should be processed when a dual-tone multifrequency (DTMF) tone is not received.
Display
Settings
Related Programming
Refer to individual features in the Electra Elite IPK Features and Specifications Manual.
Notes
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
NORMAL RELEAS
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 +
JH
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
1.
When NORMAL is selected, and a DTMF tone is not received during the Automated Attendant message or
during the Automated Attendant Push Button Receiver (PBR) Release Time (20-second default), the system
rings selected stations using Memory Block 4-01 [CO/PBX Ring Assignment (Day Mode)] or Memory Block 4-02
[CO/PBX Ring Assignment (Night Mode)].
2.
When RELEAS is selected, and a DTMF tone is not received during the Automated Attendant message or during
the Automated Attendant PBR Release Time (20-second default), the system drops the call after 30 seconds
regulated by a fixed time.
System Mode
1
Submode
4
Data No.
08
PC Programming
¦
+AU
0 8 : A A
R E S
N O R M A L
T I M E
D I S P L A Y
Setting
Data
Title
Data
No.
Summary of Contents for ElectraElite IPK
Page 2: ...PROGRAMMING MANUAL Stock Number 750825 Document Revision 1 Release 1000...
Page 3: ......
Page 5: ......