2 - 398
Programming Manual
___________________________________________________________________________________
Document Revison 1
Elite IPK
___________________________________________________________________________________
3-19
Tie Line/CO/PBX Incoming Signal
Detect Time Selection
General Description
Use this Memory Block to specify the time after the incoming signal from another
system is detected before the acknowledge signal is sent out.
Display
Settings
Page 1 – Wink Start
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default for each
method.
00 (0 ms.)
01 (130 ms.) 02 (260 ms.) 03 (390 ms.) 04 (520 ms.) 05 (650 ms.) 06 (780 ms.) 07 (910 ms.)
Page 2
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
08 (1040
ms.)
09 (1170
ms.)
10 (1300
ms.)
11 (1430
ms.)
12 (1560
ms.)
13 (1690
ms.)
14 (1820
ms.)
15 (1950
ms.)
Page 1 – Delay
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
00 (0 ms.)
01 (30 ms.)
02 (60 ms.)
03 (90 ms.) 04 (120 ms.) 05 (150 ms.) 06 (180 ms.) 07 (210 ms.)
Page 2
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
08 (240 ms.) 09 (270 ms.) 10 (300 ms.) 11 (330 ms.) 12 (360 ms.) 13 (390 ms.) 14 (420 ms.) 15 (450 ms.)
Page 1 – COI
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
00 (50 ms.) 01 (100 ms.) 02 (150 ms.) 03 (200 ms.) 04 (250 ms.) 05 (300 ms.) 06 (350 ms.) 07 (400 ms.)
Page 2
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
08 (450 ms.) 09 (500 ms.) 10 (550 ms.) 11 (600 ms.) 12 (650 ms.) 13 (700 ms.) 14 (750 ms.) 15 (800 ms.)
Programming Procedures
1
Go off-line.
2
Press LK3 +
G
+
AI
to access the Memory Block.
CO/PBX Line Mode
3
Submode
—
Data No.
19
PC Programming
¦
+BCT
0 1 / 1 9 : I N C
0 3
| 1
T I M E
D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Page
No.
Setting
Data