Elite IPK
Document Revision 1
Programming Manual
A - 3
___________________________________________________________________________________
___________________________________________________________________________________
Second Delay
Announcement
Repeat Interval
Time Selection
1-1-75
The time (seconds) to repeat
the Second Delay
Announcement.
0
20
∞
Delayed Ringing
Time Assignment
(CO)
1-1-77
The time for delayed ringing on
incoming outside line calls.
00s
15s
99s
ISDN DTMF
Duration/Interdigit
Selection
1-1-80
The tone duration/interdigit
time (milliseconds) of DTMF
signals.
70/60
100/70
900/200
ISDN Dial Interval
Time Selection
1-1-81
The time between each digit
dialed.
2s
4s
32s
Internal Paging
Timeout Selection
1-2-00
The time allowed for paging.
90s
90s
∞
Automatic Callback
Release Time
Selection
1-2-02
Time allowed before Automatic
Callback is automatically
canceled.
30s
30m
30m
Call Forward - No
Answer Time
Selection
1-2-22
The time before ICM or Trunk
calls are forwarded when there
is no answer.
4s
8s
60s
System Call Park
Recall Time
Selection
1-2-23
Time (minutes) before a parked
call recalls to the station that
parked the call.
0.5
1.0
10.0
Delayed Ringing
Time Assignment
(ICM)
1-2-26
The delayed ringing time on
incoming internal calls.
00
10s
99
PS Out of Area
Time Assignment
1-2-30
The retry time when PS is Out
of Area.
00
08s
99
Bounce Protect
Time Selection
1-3-01
The time for detecting a valid
off-hook that is long enough to
prevent unintentional bounce
as an off-hook indication from a
Single Line Telephone or Voice
Mail System.
0ms
300ms
1500ms
First Digit PBR
Release Time
Selection
1-3-03
The time that a receiver is
connected when a DTMF
Single Line Telephone user is
dialing.
10s
10s
60s
Table A-1 Function Time Chart (Continued)
Time
Memory
Block
Definition
Value
Minimum
Default
Maximum
Summary of Contents for ElectraElite IPK
Page 2: ...PROGRAMMING MANUAL Stock Number 750825 Document Revision 1 Release 1000...
Page 3: ......
Page 5: ......