Electra Elite IPK
Document Revision 4
General Description Manual
5 - 3
___________________________________________________________________________________
___________________________________________________________________________________
Table 5-2
Electra Elite/D
term
Series E Multiline Terminal Loop Resistance
and Cable Length
Terminal or Adapter
Maximum
Loop
Resistance
(Ohms)
Maximum Feet
by Twisted
1-Pair Cable
24 AWG
Maximum Feet
by Twisted
2-Pair Cable
24 AWG
DBM(B)-U( ) Box
N/A
900
900
DCU-60-1 CONSOLE
,
N/A
1000
1000
DTU-8-1 TEL
DTP-8-1 TEL
35
600
1000
DTU-8D-2 TEL
DTP-8D-1 TEL
35
600
1000
DTU-16-1 TEL
DTP-16-1 TEL
26
450
900
DTU-16D-2 TEL
DTP-16D-1 TEL
26
450
900
DTP-16HC-1 TEL
,
57
1083
DTU-32-1 TEL
DTP-32-1 TEL
21
360
720
DTU-32D-2 TEL
DTP-32D-1 TEL
21
360
720
DTR-2DT-1 TEL
35
600
1000
DTR-4D-1 TEL
37
700
1400
DTR-4R-1/2 TEL
N/A
650
1000
DTH-4R-1/2 TEL
N/A
650
1000
SLT(1)-U( ) ADP
,,
35
600
1000
DP-D-1
20
410
820
,
An AC Adapter is required for the DTP-16HC-1 TEL or 60-button Attendant Console
DCU-60-1.
,,
The length for the specified SLT Adapter is the length between the SLT Adapter and the
ESI
.
Summary of Contents for ElectraElite IPK
Page 2: ...GENERAL DESCRIPTION MANUAL INT 1024 IPK Document Revision 4 Release 4000 4500...
Page 3: ......
Page 5: ......
Page 8: ...Regulatory Information...
Page 25: ...Chapter 1 Introduction...
Page 54: ...Chapter 2 Features...
Page 103: ...Chapter 3 Equipment...
Page 124: ...Chapter 4 Installation Programming and Maintenance Overview...
Page 129: ...Chapter 5 Hardware Specifications...
Page 150: ...GENERAL DESCRIPTION MANUAL NEC Unified Solutions Inc Document Revision 4 Release 4000 4500...
Page 151: ......