7-26 Troubleshooting
SCSI device timeout appears in the system event log:
→
This symptom occurs when the processing speed of HDDs is slower than the
request from the operating system. The process will be continued properly by the
retry function.
It is likely to occur when the server shifts from the simplex mode to the duplex
mode at OS startup or during maintenance operations. If the number of the
following errors recorded in the system event log is few, ignore the errors.
This error is logged about 5 times when the server shifts from the simplex mode to
the duplex mode during maintenance operations. Ignore these errors as well.
Source: adpu320
Type: Error
EventID: 9
Description: The device, \Device\Scsi\adpu320xx, did not respond within the
timeout period.
Source: adpu320
Type: Error
EventID: 117
Description: The driver for device \Device\Scsi\adpu320xx detected a port
timeout due to prolonged inactivity. All associated busses were
reset in an effort to clear the condition.
If this error is recorded many times, the hard disk drive may be faulty. Contact
your service representative.
Event log which warn CPU load monitoring is registered:
→
If NEC ESMPRO Agent cannot get performance information from the OS due to a
temporary resource shortage or high load ratio on the system, it will record the
following event log. However, there is no real problem on operation. (In the
description, Y and X represent alphanumeric characters.)
Source: ESMCpuPerf
Type: Information
Event ID:
9005
Description: Cannot get system performance information now (YYYY
Code=xxxx).
If NEC ESMPRO Agent cannot get information, it will treat the load ratio as 0%.
So, if NEC ESMPRO Agent cannot get information continuously, the CPU load
ratio may appear lower than the actual value.
Error log is registered on the OS start:
→
The following event may be registered when the OS starts. This log may also be
registered when the ftSys SSN service functions normally.
Source:
Service Control Manager
Type: Error
Event ID:
7022
Description: Description: ft Sys SSN service hung on starting.
Summary of Contents for EXP320J
Page 12: ... THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 25: ...xiii APPENDIX A SPECIFICATIONS A 1 APPENDIX B I O PORT ADDRESSES B 1 ...
Page 26: ...xiv THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 28: ...1 2 Precautions for Use 使用上的注意 本章包含著對服務器恰當安全的操作必要的信息 ...
Page 54: ...1 28 Precautions for Use This page is intentionally left blank ...
Page 64: ...2 10 General Description Rear View ...
Page 68: ...2 14 General Description CPU IO Module CPU IO module ...
Page 88: ...2 34 General Description This page is intentionally left blank ...
Page 100: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled ...
Page 218: ...4 92 System Configuration This page is intentionally left blank ...
Page 390: ...5 172 Installing and Using Utilities This page is intentionally left blank ...
Page 408: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1 ...
Page 410: ...6 20 Maintenance This page is intentionally left blank ...
Page 454: ...7 44 Troubleshooting This page is intentionally left blank ...
Page 485: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035 ...
Page 500: ......
Page 503: ......