2. BMC Configuration
Express5800/E120g-M Maintenance Guide
109
Chapter 2 Useful Features
2.4.6
Miscellaneous
The following items are available when you select
Miscellaneous
in BMC Configuration menu.
Item Description
Default
Value
Miscellaneous
Behavior
when
SEL
repository is Full
Specify the behavior when SEL repository is full.
*1
Stop logging SEL
: Any new SEL is not recorded.
Clear all SEL
: Erase all SEL and record a new SEL.
Overwrite oldest SEL
: Old SEL is overwritten with new SEL.
Overwrite oldest
SEL
Platform Event Filter
Enable or disable Platform Event Filter.
*2
Enable
Management
Software
Setting for remote management
–
ESMPRO
Management
Enable or disable BMC management by NEC ESMPRO
*3
Current set value
Authentication Key
Specify the Authentication Key.
*4
*5
guest
Redirection
Enable or disable Redirection feature.
*4
*6
Enable
*1: When this item is changed to/from "Overwrite oldest SEL", all log records in the SEL Repository are cleared.
*2: Disabling Platform Event Filter also disables SNMP alert.
*3: When BMC can be managed directly from NEC ESMPRO Manager (Ver.5.4 or later), this item must be set to "Enable". If it is
set to "Enable", Authentication Key is required.
*4: Can be specified only when ESMPRO Management is set to "Enable".
*5: This Authentication key is used when NEC ESMPRO Manager (Ver.5.4 or later) manages the target server. Up to 16
alphanumeric characters are accepted.
*6: If Redirection is set to "Enable", Console Redirection port in BIOS is set to "Serial Port B" at next boot.
Note
If you do not use remote management feature by NEC ESMPRO, set to "Disable" for
ESMPRO Management in Management Software. In this case, setting for relevant items
are hidden and unnecessary..