1. POST Error Message
Express5800/E120g-M Maintenance Guide
172
Chapter 3 Appendix
Error Message
Cause
Action
C10E
BMC SDR Repository empty.
An error was detected on BMC SDR.
Unplug the power cord, wait for at least 30
seconds, and then restart the server.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
An error was detected in FRU that
contains device information.
C111 BMC
SDR Repository failure.
Failure was detected in SROM that
stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in BMC
SEL.
C113
BMC RAM test error.
An error was detected in BMC RAM.
C114
BMC Fatal hardware error.
A hardware error was detected in
BMC.
C115 Management
controller
not responding
Management controller does not
respond.
Update the BMC firmware.
C116
Private I2C bus not
responding.
Private I2C bus does not respond.
Turn off the power and unplug the power
cord, wait for at least 30 seconds, and then
restart the server.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data was
detected.
C11A SEL
corrupt.
BMC error or illegal system event log
data was detected.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not installed.
Contact your sales representative.
C11C
BMC Mezzanine partition is
invalid.
A format error was detected in BMC
Mezzanine card.
C11D
BMC is in Forced Boot Mode.
Detected that BMC is in Forced Boot
Mode.
Turn off the power, unplug the power cord,
and check the jumper switch setting on
motherboard. Wait for at least 30 seconds,
and then restart the server.
C11E
Communication with BMC was
failed in previous boot
Communication with BMC was failed
in previous boot
Turn off the power and unplug the power
cord, wait for 30 seconds, and then reboot
the server.
C11F
Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on BMC
mezzanine card.
Contact your sales representative.
C200
The error occurred during
memory configuration check.
Memory configuration could not be
obtained.
C201 Memory
Configuration change is
detected.
The memory configuration has
changed since the previous startup.
When
Check previous system Config
is
enabled in
Server
menu of the setup, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no
configuration change has been made,
contact your service representative.
C202
The error occurred during CPU
configuration check.
The CPU information could not be
obtained.
Contact your service representative.
C203
CPU Configuration change is
detected.
The CPU configuration has changed
since the previous startup.
When
Check previous system Config
is
enabled in
Server
menu of the setup, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no
configuration change has been made,
contact your service representative.
C300 Out-of-band
setup
configuration failure
Configuration change requested by
remote terminal via network failed.
Turn off the power and unplug the power
cord, wait for at least 30 seconds, then
restart the server.
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data record
was detected
Contact your sales representative.
C302
Hardware configuration
error.
Illegal hardware configuration was
detected.
C303
FAN Structure ID command
error.
Illegal fan control was detected when
RAID Controller is installed.