1. POST Error Message
Express5800/E120g-M Maintenance Guide
173
Chapter 3 Appendix
Error Message
Cause
Action
C304
Necessary to update SDR
Version for new RAID Card.
SDR for RAID Controller is
inappropriate.
Contact your sales representative.
C320 Unmatched PSUs.
Unmatched power supply units are
configured.
C321 System power consumption is
out-of-range in PSUs.
System power consumption exceeds
the power output capacity limit.
C322 No information for system
power consumption check.
No information is acquired in checking
system power consumption.
C323
Internal Use Area of BMC FRU is
incompatible.
The FRU of hardware information is
incompatible.
Turn off the power and unplug the power
cord, wait for at least 30 seconds, then
restart the server.
C324 Unsupported
combination
of
module enclosure and server
module.
Unsupported combination of module
enclosure and server module.
Implement a correct combination of module
enclosure and modular server. If the
problem persists, contact your sales
representative..
C325
ME is in Recovery Mode
Cannot read module enclosure FRU.
Restart the server. If the same error is
continuously detected, restart the device
after unplugging the power cord of all the
modular servers and after waiting for at
least 30 seconds.
C501 Intel(R) Node Manager is in
Recovery Mode.
Intel Node Manager is in Recovery
Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that
time, check the jumper switch setting on
motherboard.
C600
Internal Flash is not valid.
Selected Internal Flash Memory as a
onetime booting device but failed to
enable it.
Turn off the power, unplug the power cord,
and check the jumper switch setting on
motherboard. Wait for at least 30 seconds,
and then restart the server.
C624
Invalid internal BIOS
Configuration Data.
An internal error was detected during
sending BIOS Configuration Data.
Turn off the power and unplug the power
cord, wait for at least 30 seconds, then
restart the server.
C625
BIOS Configuration Data Send
Error.
An internal error was detected during
reading BIOS Configuration Data.
C626
BIOS Configuration Data Read
Error.
An internal error was detected during
writing BIOS Configuration Data.
C627
BIOS Configuration Data Write
Error.
The SETUP setting was cleared by
Set System Boot Options of the
standard IPMI command.
C628
System configuration data
cleared by System Boot Options
command.
An internal error was detected during
sending BIOS Configuration Data.
Run SETUP and specify each item.