1. POST Error Message
Express5800/E120g-M Maintenance Guide
178
Chapter 3 Appendix
BMC Message on Lower LCD Line
Cause
Action
CPU2-DIMM1 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM1.
CPU2-DIMM2 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM2.
CPU2-DIMM3 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM3.
Contact your sales representative.
CPU2-DIMM4 Uncorrectable Error
An uncorrectable error occurred
for CPU2-DIMM4.
CPU2-DIMM5 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM5.
CPU2-DIMM6 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM6.
CPU2-DIMM7 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM7.
CPU2-DIMM8 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM8.
Processor1 Internal Error
An internal CPU error (IERR)
occurred.
Processor2 Internal Error
Sensor Failure Detected.
Abnormality in a sensor was
detected.
SMI timeout
A timeout occurred while
servicing system management
interrupts.
Soft Power Control Failure
Power-on is inhibited.
IPMI Watchdog timer timeout
(Power off)
A watchdog timer timeout
occurred.
Node Manager Firmware Image
execution Failed
Abnormality in Node Manager
occurred.
Turn off the power, wait for at least 30
seconds, and restart the server.
Node Manager Firmware Flash Erase
Error
Node Manager Firmware Flash
Corrupted
Node Manager Internal Error
Node Manager can't communicate
BMC
Node Manager Manufacturing Error
Node Manager Persistent Storage
Integrity Error
Node Manager Firmware Exception
Node Manager Flash Wear-Out
Protection Warning
Drive 0 Fault
Operation was performed during
hard disk drive failure
Turn off the power, wait for at least 30
seconds, and restart the server.
Drive 1 Fault
Drive 2 Fault
Drive 3 Fault
System Rear FAN1 Lower
Non-Critical
A fan alarm was detected.
A cooling fan has failed or is clogged.