2. List of Windows Event Logs
Express5800/E120g-M Maintenance Guide
184
Chapter 3 Appendix
Applications and Services Logs
200
Microsoft-Windows-
DeviceSetupManager
Warning
A connection to the Windows Update Services could not be established.
When running the system
If this event is not registered after the Internet connection is established,
there is no problem in system operation.
201
Microsoft-Windows-
DeviceSetupManager
Warning
A connection to the Windows Metadata and Internet Services (WMIS)
could not be established.
When running the system
If this event is not registered after the Internet connection is established,
there is no problem in system operation.
202
Microsoft-Windows-
DeviceSetupManager
Warning
The Network List Manager reports no connectivity to the internet.
When running the system
If this event is not registered after the Internet connection is established,
there is no problem in system operation.
215
Microsoft-Windows-
AppReadiness
Error
'ART:ResolveStoreCategories' of Administrator failed.
Error: 'Class not registered' (0.0469065 sec.)
When installing an OS
If this event is logged only at the first sign-in after OS installation and
does not occur repeatedly, there is no problem in system operation.
Windows Server 2012
System Log
4
b57nd60a
Warning
Broadcom NetXtreme Gigabit Ethernet #xx: The network link is down.
Check to make sure the network cable is properly connected.
When installing an OS, starting system,
or applying Starter Pack
This event does not affect system operation.
4
l2nd
Warning
QLogic BCM57810 #xx: The network link is down. Check to make sure
the network cable is properly connected.
When installing an OS, starting system,
or applying Starter Pack
This event does not affect system operation.
24
mlx4_bus
Warning
MLX4_SF_32_0_0:
Problem - The port was configured to use auto sensing for
port type. The port * failed to detect the port type automatically.
Impact - As a result the port is started as IB port (unless the port is
ETH only). This may cause a connection problem if the other side is
ETH port.
Reason and suggestion to fix - This problem may happen since the
computer is connected back to back or the cable is unplugged.
For solving this issue connect the port to a switch or define the port type
explicitly (IB or ETH) instead of auto.
* There may be cases that the above message is somewhat different.
At the time of system start-up
This event is logged in the system when InfiniBand Adapter is
connected. This event will be recorded when the type of port could not
be recognized automatically such as InfiniBand cable is not connected.