5. Troubleshooting
Express5800/E120g-M Maintenance Guide
26
Chapter 1 Maintenance
Check if "Shutdown System" is enabled on ECO menu.
→
Confirm the ECO settings from a remote machine. If the remote environment is unavailable, remove the
optional devices from the server to reduce power consumption of overall system, then restart the server.
→
Check if the value specified for “Power Threshold (Pa)” is appropriate for normal startup.To operate the
server with “Shutdown System” being enabled, the value of “Power Threshold (Pa)” must be fully
considered.
5.2
Problem at Starting EXPRESSBUILDER
[?]
Unable to start EXPRESSBUILDER from Internal Flash Memory
Did you press <F3> key to start EXPRESSBUILDER from Internal Flash Memory during POST?
→
After starting the server, press <F3> key when the following message appears.
Press <F2> Setup, <F3> Internal Flash Memory, <F4> ROM Utility, <F12> Network
Have you inserted a CD/DVD or removable media to the server?
→
Remove a CD/DVD and removable media from the server and try again.
Is the data of Internal Flash Memory broken?
→
Run EXPRESSBUILDER from DVD, perform
Update
of
Internal Flash Memory
in Utility menu, and try
again.
Is an error message displayed?
→
Take an appropriate action depending on the message.
Error [Message ID:Z3001]:
Unable to start EXPRESSBUILDER. Virtual Drive (VD) is incorrect.
Action: Go the web site below to find recovery file.
http://www.nec.com/
Error [Message ID:Z3002]:
Failed to detect a DVD drive or a flash drive.
Action: Check if hardware is properly connected.
Error [Message ID:Z3003]:
Failed to read a file.
Action: Check if DVD is damaged or not.