3. Power Control Feature
Express5800/R120g-1M, R120g-2M Maintenance Guide
121
Chapter 2 Useful Features
3.
Power Control Feature
For a device that has a Xeon Processor, power consumption of the server can be controlled by using the
command line interface of EXPRESSSCOPE Engine 3 (BMC) or by using NEC ESMPRO Manager. This
feature curves the upper limit of the power consumption, which allows more servers to be installed in the
environment where the power consumption is limited.
For settings information, see
EXPRESSSCOPE Engine3 User’s Guide
or
NEC ESMPRO Manager online help
.
3.1
Supported OS
The power control feature is available for the following OSs.
•
Windows Server 2008 R2, Standard x64
•
Windows Server 2008 R2, Enterprise x64
•
Windows Server 2012 Standard x64
•
Windows Server 2012 Datacenter x64
•
Windows Server 2012 R2 Standard (x64)
•
Windows Server 2012 R2 DataCenter (x64)
3.2
Notes on Using Windows Server 2008 R2 / 2012 / 2012 R2
Ignore the following event when Windows Server 2008 R2, 2012, or 2012 R2 is run on the server. This event is
logged at the normal operation of controlling the server power.
Source: Kernel-Processor-Power
Event ID: 37
Level: Warning
User: SYSTEM
Source: Kernel-Processor-Power
Event ID: 37