1. POST Error Message
Express5800/R120g-1M, R120g-2M Maintenance Guide
145
Chapter 3 Appendix
Error Message
Cause
Action
B277 PCI
Slot 3C - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 3C.
B278 PCI
Slot 1D - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 1D.
B279
PCI Slot 2D - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 2D.
B27A
PCI Slot 3D - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 3D.
B800
DXE_PCI_BUS_OUT_OF_RESOURCES
Resources to be allocated to
PCI expansion card was
insufficient.
C000
The error occurred during
fan sensor reading.
An error was detected while
reading fan sensor.
C010
The error occurred during
temperature sensor reading
An error was detected while
reading temperature sensor.
C011
System Temperature out of
the range.
A temperature abnormality was
detected.
The cooling fan has failed or is clogged.
Contact your sales representative.
C020
The error occurred during
voltage sensor reading.
An error was detected while
reading voltage sensor.
Contact your sales representative.
C021
System Voltage out of the
range.
A system voltage abnormality
was detected.
C040
SROM data read error
An error was detected while
reading data on SROM.
C061
1st SMBus device Error
detected.
An error was detected on 1st
SM Bus.
C062
2nd SMBus device Error
detected.
An error was detected on 2nd
SM Bus.
C063
3rd SMBus device Error
detected.
An error was detected on 3rd
SM Bus.
C064
4th SMBus device Error
detected.
An error was detected on 4th
SM Bus.
C065
5th SMBus device Error
detected.
An error was detected on 5th
SM Bus.
C066
6th SMBus device Error
detected.
An error was detected on 6th
SM Bus.
C067
7th SMBus device Error
detected.
An error was detected on 7th
SM Bus.
C068
8th SMBus device Error
detected.
An error was detected on 8th
SM Bus.
C101
BMC Memory Test
Failed.
An error was detected on BMC. Unplug the power cord, wait for at least 30
seconds, then restart the server.
C102
BMC Firmware Code
Area CRC check Failed.
C103 BMC
core
hardware failure.
C104 BMC
IBF or OBF check failed.
An error was detected while
accessing BMC.
C105
BMC SEL area full.
There is not enough space to
store the system event log.
Run Offline Tools and delete the event logs.
C10B
BMC operational code
corrupted.
An illegality was detected while
updating BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server.