1. POST Error Message
Express5800/R120g-1M, R120g-2M Maintenance Guide
146
Chapter 3 Appendix
Error Message
Cause
Action
C10C
BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server.
C10D Internal
Use Area of BMC FRU
corrupted.
An illegality was detected in
FRU containing the device
information.
C10E
BMC SDR Repository empty.
An error was detected on BMC
SDR.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
An error was detected in FRU
that contains device
information.
C111 BMC
SDR Repository failure.
Failure was detected in SROM
that stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in
BMC SEL.
C113
BMC RAM test error.
An error was detected in BMC
RAM.
C114
BMC Fatal hardware error.
A hardware error was detected
in BMC.
C115 Management
controller
not responding
Management controller does
not respond.
Update the BMC firmware.
C116
Private I2C bus not
responding.
Private I2C bus does not
respond.
Unplug the power cord, wait for at least 30
seconds, then restart the server.
C117
BMC internal exception
BMC internal error was
detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was
detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data
was detected.
C11A SEL
corrupt.
BMC error or illegal system
event log data was detected.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not
installed.
Contact your sales representative.
C11C
BMC Mezzanine partition is
invalid.
A format error was detected in
BMC Mezzanine card.
C11D
BMC is in Forced Boot Mode.
Detected that BMC is in Forced
Boot Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on motherboard.
C11E
Communication with BMC was
failed in previous boot
Communication with BMC was
failed in previous boot
Unplug the power cord, wait for at least 30
seconds, and restart the server.
C11F
Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on
BMC mezzanine card.
Contact your service representative.
C120
BMC Runtime FW corrupted.
An error occurred on BMC
Runtime FW.
Disconnect the power cord, wait for at least 30
seconds, and then restart the server.
C121
BMC Force Update FW corrupted.
An error occurred on BMC
Force Update FW.
C122
BMC Configuration area
corrupted.
An error occurred on BMC
Configuration area.
C123
BMC eMMC inaccessible.
Failed to access to BMC
eMMC.
C125
BMC eMMC mode error.
BMC eMMC mode error
C126
BMC eMMC partition corrupted.
An error occurred on BMC
eMMC partition.
C127
BMC eMMC format corrupted.
A format error occurred on BMC
eMMC.
C128
BMC is in Update Mode.
BMC is in update mode.
C300 Out-of-band
setup
configuration failure
An error was detected while
accessing BMC Mezzanine
card.
Unplug the power cord, wait for at least 30
seconds, then restart the server.
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected
Contact your sales representative.