2. List of Windows Event Logs
Express5800/R120g-1M, R120g-2M Maintenance Guide
164
Chapter 3 Appendix
11
iANSMiniport
Warning
Adapter link down:Intel(R) ~
When starting system
This event is logged at system startup if a team is configured with
Intel(R) PROSet, however, there is no problem in system operation.
13
iANSMiniport
Warning
Intel(R) ~ has been deactivated from the team.
When starting system
This event is logged at system startup if a team is configured with
Intel(R) PROSet, however, there is no problem in system operation.
16
iANSMiniport
Warning
Team #0: The last adapter has lost link. Network connection has been
lost.
When starting system
This event is logged at system startup if a team is configured with
Intel(R) PROSet, however, there is no problem in system operation.
22
iANSMiniport
Warning
Primary Adapter does not sense the following Probes:
Intel(R) ~ Possible reason: partitioned Team.
When starting system
This event is logged at system startup if a team is configured with
Intel(R) PROSet, however, there is no problem in system operation.
27
e1rexpress
Warning
Intel(R) Ethernet Server Adapter I340-T2 #xx
Network link is disconnected.
When starting system, or applying
Starter Pack
This event does not affect system operation.
134
Microsoft-Windows-
Time-Service
Warning
NtpClient was unable to set a manual peer to use as a time source
because of DNS resolution error on ' '. NtpClient will try again in
3473457 minutes and double the reattempt interval thereafter.
When installing an OS
This event does not affect system operation.
1004
IPMIDRV
Warning
The IPMI device driver attempted to communicate with the IPMI BMC
device during normal operation.
However the communication failed due to a timeout.
You can increase the timeouts associated with the IPMI device driver.
When running the system
The above event log may be recorded. Usually, however, IPMI
command retry processing is performed, so there is no operation
problem.
7023
Service Control Manager
Error
The
WMI Performance Adapter service terminated with the following
error: The error cannot be identified.
When starting an OS or shutting down
an OS
Ignore this error because there is no impact on the system.
Application Event Log
63
Microsoft-Windows-WMI
Warning
A provider, BnxWmiProvider, has been registered in the Windows
Management Instrumentation namespace root\brcmbnxns to use the
LocalSystem account. This account is privileged and the provider may
cause a security violation if it does not correctly impersonate user
requests.
Upon applying Starter Pack
This event does not affect system operation.
63
Microsoft-Windows-WMI
Warning
A provider, BnxWmiProvider, has been registered in the Windows
Management Instrumentation namespace root\interop to use the
LocalSystem account. This account is privileged and the provider may
cause a security violation if it does not correctly impersonate user
requests.
Upon applying Starter Pack
This event does not affect system operation.