1. System BIOS
Express5800/R120g-1M, R120g-2M Maintenance Guide
98
Chapter 2 Useful Features
(2)
Power Control Configuration submenu
From the
Server
menu, move the cursor to
Power Control Configuration
and then press the <Enter> key to
show its submenus.
For details about the options, see the table below.
Option Parameter
Description
AC-LINK
Stay Off
[Last State]
Power On
Specify the AC linking feature. Specify how the DC power
state should be when the AC power is supplied again after
loss of power. (See the table below)
Power ON Delay Time Mode
[Manually Setting]
Random
Select a method to specify the delay time before powering
on DC power. Available options are: "User-specified value"
or "random value".
This option is selectable when
AC-LINK
is set to "Power
On" or "Last State".
Delay Time
[45]-600
Specify the delay time in unit of seconds.
The minimum configurable time may be changed from the
factory-set value.
The minimum configurable time is displayed when
executing
Load Setup Defaults
.
This menu appears when
Power ON Delay Time Mode
is
set to "Manually Setting".
Standby Power Save
[Disabled]
Enabled
Enable or disable the feature that saves the standby power
on standby. If this option is set to "Enabled", the
AC-LINK
setting is fixed to "Power On" automatically and cannot be
changed. When the AC power is off, management,
monitoring, and power-on of the server are disabled on a
remote site. Powering on the server is available only by
pressing the POWER switch on the server.
If the AC-LINK setting is changed on a remote site with this
option being set, you need to press the POWER switch
twice to power on the server.
Cold Redundant Mode
[Disabled]
Enabled
Enable or disable the Cold Redundancy feature.
For details, refer to User's Guide.
R120g-1M:Chapter 2 (1.17.1 Cold Redundant Feature)
R120g-2M:Chapter 2 (1.27.1 Cold Redundant Feature)
[ ]: Factory setting