2. Description on System Utility
Express5800/R120h-2M (2nd-Gen) User’s Guide
235
Chapter 3 Setup
2.4
Cases that Require Configuration
If any of the following cases are applicable, operate in System Utility to change parameters from the factory
preset. Other than cases described below, do not change the settings. The catalog of parameters in System
Utility and the factory presets can be found in
Chapter 1 (1. System Utility)
of
Maintenance Guide (Common)
.
(1/4)
Category
Description
To be changed
Remark
Settings to
be saved in
the user
default
Items to be set at all
times
Set to
Allow Operation with Critical Fan
Failure
at
System Configuration >
BIOS/Platform Configuration (RBSU) >
Advanced Options > Fan and Thermal
Options > Fan Failure Policy
.
At the time of shipment,
Fan Failure Policy
is set
to
Allow Operation with
Critical Fan Failures
.
Set
System Configuration > BIOS/Platform
Configuration (RBSU) > System Options >
USB Options > Internal SD Card Slot
to
Disabled
.
At the time of shipment,
Internal SD Card Slot
is
set to
Disabled
.
Set to
Custom
at
System Configuration >
BIOS/Platform Configuration (RBSU) >
Workload Profile.
At the time of shipment,
Workload Profile
is set to
Custom.
Set to
No C-states
at
System Configuration >
BIOS/Platform Configuration (RBSU) > Power
and Performance Options > Minimum
Processor Idle Power Core C-State.
At the time of shipment,
Minimum Processor Idle
Power Core C-State
is set
to
No C-states.
Set to
No Package States
at
System
Configuration > BIOS/Platform Configuration
(RBSU) > Power and Performance Options >
Minimum Processor Idle Power Package C-
State.
At the time of shipment,
Minimum Processor Idle
Power Package C-State
is
set to
No Package States.
Setting up the
Time
Format
in accordance
with your OS
・
If you use Windows or Linux
Set to
Coordinated Universal Time (UTC)
at
System Configuration > BIOS/Platform
Configuration (RBSU) > Date and Time]-[Time
Format.
Set up following the pre-
install checklists in the
installation guide below.
・
If you use Windows
For Windows: Chapter 1
Installing Windows
・
If you use another OS
Set up following the pre-install checklist in the
installation guide of your OS.
If you use the
NEC ESMPRO
ServerAgentService
Set to
Disabled
at
System Configuration >
BIOS/Platform Configuration (RBSU) >
Advanced Options > Fan and Thermal
Options > Thermal Shutdown
.
At the time of high
temperature, shutdown is
executed by
NEC ESMPRO
ServerAgentService