TM700 User Guide - Setting Up the System
2 - 3
Selecting a Site
The system operates reliably in a typical office environment.
Choose a site that is:
■
Near grounded, three-pronged power outlets.
Note
:
For the United States and Canada, this means a
NEMA 6-15R outlet for 200-240 VAC. The system cannot be
used on a NEMA 5-15R outlet for 100-120 VAC. For other
international sites, this means three-pronged power outlets
applicable for the electrical code of the region.
WARNING
Be sure the power service connection is through a properly
grounded outlet.
CAUTION
When two power supplies are installed in the system the power
plug from each of the power supplies must be plugged into the
same common ground power outlets.
■
Clean, dust-free, and well ventilated. Every side ventilating openings kept free of
obstructions. Away from sources of heat, vibration or physical shock.
■
Isolated from strong electromagnetic fields and electrical noise produced by
electrical devices (such as air conditioners, large fans, large electric motors, radio
and TV transmitters, and high-frequency security devices)
■
Spacious enough to provide at least ten inches (25 centimeters) in front of the
system, five inches (13 centimeters) behind the system and three inches (eight
centimeters) on each side of the system for proper cooling, airflow, and cable
clearance.
■
Easily accessible for system maintenance and installation of system upgrades.
!
Summary of Contents for Express 5800 TM700
Page 1: ...User s Guide Express 5800 TM700...
Page 2: ......
Page 8: ......
Page 44: ...TM700 User Guide Setting Up the System 2 10...
Page 100: ...TM700 User Guide Upgrading Your System 4 40...
Page 114: ...TM700 User Guide Problem Solving 5 14...
Page 118: ...TM700 User Guide Appendix B B 2...
Page 122: ...TM700 User Guide Appendix C C 4...
Page 131: ......
Page 132: ......