4-7 Troubleshooting
On-screen error message
Description
Cause
Action
8122 Unsupported DIMM
detected in DIMM
group #3
8130 Mismatch DIMM
Type detected in
DIMM group #1.
8131 Mismatch DIMM
Type detected in
DIMM group #2.
8132 Mismatch DIMM
Type detected in
DIMM group #3.
The type of DIMM is
not in agreement.
1. Check that DIMMs of the
same type are installed in
groups.
2. Replace DIMMs.
8140 DIMM group #1 with
error is enabled.
Failed DIMM in group
#1 was detected.
Replace both DIMMs.
8141 DIMM group #2 with
error is enabled.
Failed DIMM in group
#2 was detected.
8142 DIMM group #3 with
error is enabled.
Failed DIMM in group
#3 was detected.
8150 NVRAM Cleared By
Jumper
NVRAM was cleared
by jumper setup.
Incorrect jumper
setting
Turn off power and change
the jumper setting back to
its default position.
8160 Mismatch Processor
Speed detected on
Processor 1
The frequency of
processor 1 is not
correct.
Processor errors
8161 Mismatch Processor
Speed detected on
Processor 2
The frequency of
processor 2 is not
correct.