Hardware
165
Power-OFF and Stopping Server
Note that the procedure of turning the power OFF differs depending on the server boot status.
Refer to the guide accompanied with UPS or the guide for application that controls UPS when
the server is connected to UPS.
There are 4 methods to turn the power OFF by shutting down OS and stopping the server
as shown below.
(1) Shutting down from OS.
(2) Operate the navigation button of EXPRESSSCOPE® Monitor and perform the
procedure from Operation Menu.
For A1080a-S Model/A1080a-E Model/A1040a Model
●
When shutting down OS of Server 1
Go to
[Main Menu]
->
[All Servers Up/Down]
->
[SVRs OS Shutdown]
->
[Execute]
or,
Go to
[Main Menu]
->
[Server1]
->
[SVR1
Control]
->
[SVR1
OS Shutdown]
->
[Execute].
↓
↓
↓
●
When step (1) is performed while OS is running, the steps (2) and (3)
are performed automatically.
●
When step (2) is performed while OS is not running and the server
is running (BIOS menu, etc.), the step (3) is performed automatically.
OS Shutdown
Stop the server
Power-OFF
Turn OFF the power of peripherals
· · · · · · · · · · · · · · · · · · · · · · · · (4)
The following shows the flow of steps from OS shutdown to power-OFF.
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · (3)
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · (2)
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · (1)
Summary of Contents for Express 5800
Page 73: ...73 Memo ...
Page 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Page 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Page 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Page 573: ...573 Memo ...
Page 583: ...Software 583 Memo ...
Page 690: ...Operation and Maintenance 690 Memo ...
Page 719: ...XXIX Memo ...