Operation and Maintenance
622
(5) Read the information on the
Monitoring Event Log
screen as necessary since information
listed here needs to be collected in the next procedure.
To collect event log data, right-click on the
Event Log
screen and select
“Select All (A)”
.
Then, right-click and select
“Copy (C)”
. Paste the data on the text editor. Up to 100 event
logs can be displayed at one time. Select a full-screen mode when there are 100 or more
event logs.
(6) Repeat steps from 1 to 5 above for all WEB Consoles that need to be confirmed.
4. BID
(
Build
In Diagnostic
)
Screen to show the failure on the suspected part
<
Description
>
BID : *********** Analysis Result *********************************************
1
BID : ----------- Fault Analysis Result ---------------------------------------
No. 1 DIMM [PMM0/DIMM000 ] 90%
No. 2 PMM [PMM0 ] 10%
2
BID : ----------- Fault Analysis Result (Component) ---------------------------
No. 1 ----- DIMM [PMM0/DIMM000 ] 90%
No. 2 ----- PMM [PMM0 ] 10%
3
BID : ----------- Error Information -------------------------------------------
PROC100 Memory single-bit ECC error occurred.
CELL1/PMM0/DIMM000 ADDRESS=0x0012_77FE_AF80 ECC_INFO=0x8890
Main memory DIMM patrol read data error occurred.
DIMM error information. SDRAM=No.D14, Signal(s)=DQ47
4
BID : ----------- Register Dump -----------------------------------------------
PROC100 EVENT=0004 SSB=04 AT0=000000_00000000 AT1=000004_00000000 TRN=0
BID : *************************************************************************
Replacement FRU/CRU:
The suspected failure percentage of the part is displayed based on the number of units to be
replaced when a failure occurs. The higher the suspected failure percentage for a part is, the
higher the possibility that the part is the cause of failure. However, the sum of the percentage
may not be 100, since after the decimal point is rounded off. The name of the part identified in
No.1 of the BID is displayed in
View Faults
of the LCD.
BID : ----------- Fault Analysis Result -----------------------------
No. 1 DIMM [PMM0/DIMM000 ] 90%
No. 2 PMM [PMM0 ] 10%
Whether to replace a part is determined here.
CRU
:
Customer Replaceable Unit
FRU
:
Field Replaceable Unit
Part name
Location
Suspected failure percentage
Summary of Contents for Express 5800
Page 73: ...73 Memo ...
Page 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Page 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Page 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Page 573: ...573 Memo ...
Page 583: ...Software 583 Memo ...
Page 690: ...Operation and Maintenance 690 Memo ...
Page 719: ...XXIX Memo ...