Operation and Maintenance
642
12. Execute test.
(1) Enter
<list>
command on the command line of the TeDoLi screen to display the test device
list.
The test device list is displayed in the tree structure corresponding to the installed position of
hardware.
· In
the
“Num”
row, the test device number of the test device is displayed. Specify the test
device using these test device number.
· In
the
“*”
row, selected test is displayed in
“*.”
If not selected, the test is displayed in
“ ”
(blank). If
“!”
appears on a device, it is unselectable as the test device.
· In
the
“Device List”
row, the device name of the test device is displayed.
·
No device is selected for the test device on the initial status just after starting the TeDoLi.
· The device information on the lower layer can be collapsed with
<close>
command for the
tree that
“-”
is added on the top of the device name.
· The device information on the lower layer can be expanded with
<open>
command for the
tree that
“+”
is added on the top of the device name.
· The test device type is displayed in the
“Type”
row. On this type, the test device can be
selected by using
<select/desel>
command.
· In
the
“Prev”
row, the most recently executed test result is displayed.
· In
the
“Status”
row, the current test status is displayed.
TeDoLi> list
+----+-+---------------------------------+------------+----+-------------+
| Num|*| Device List | Type |Prev| Status |
+----+-+---------------------------------+------------+----+-------------+
| 1| | MEMORY |MEMORY | | |
| 2|!|-MGM2 |MODULE | | |
| 3|!| -MGM2/MGB/GbE |NIC | | |
| 4| | Port1(eth1) |ETH-PORT | | |
| 5| | Port2(eth2) |ETH-PORT | | |
| 6|!|-PMM5 |MODULE | | |
| 7| | PMM5/PMB/PROC |CPU | | |
| 8|!|-PMM6 |MODULE | | |
| 9| | PMM6/PMB/PROC |CPU | | |
| 10|!|-BM |MODULE | | |
| 11|!| -BM/MB/PCI1 |SCSI(NoDev) | | |
| 12|!| Port1 |SCSI-PORT | | |
| 13|!| -BM/MB/PCI8 |NIC | | |
| 14| | Port1(eth0) |ETH-PORT | | |
| 15|!| -BM/MB/PCI9 |FC | | |
| 16|!| -Port1 |FC-PORT | | |
| 17| | SCSI-ID0 LUN0(iStorage 1000) |HDD | | |
| 18|!| Port2 |FC-PORT | | |
| 19| | DV-28S-V |DVD | | |
+----+-+---------------------------------+------------+----+-------------+
Summary of Contents for Express 5800
Page 73: ...73 Memo ...
Page 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Page 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Page 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Page 573: ...573 Memo ...
Page 583: ...Software 583 Memo ...
Page 690: ...Operation and Maintenance 690 Memo ...
Page 719: ...XXIX Memo ...