Operation and Maintenance
644
(3) Enter
<time>
or
<round>
command on the command line of the
System Diagnostics
screen to set the test ending condition. When the test ends by the specified time, specify
<time>
command. When the test ends by the number of test executing times, specify
<round>
command.
# In general, specify <time 15>.
The following is an example of specified command.
· When
“0”
is specified as the test ending condition, the test infinitely runs, regardless of test
time or number of rounds. The initial status just after starting the system diagnostics is loop
execution for the specified test time.
·
The test time can be specified by the minute. Test is repeatedly executed within the specified
time (minutes). After the specified time elapses, the test completes without repeating.
·
Test runs for the specified number of rounds and ends without repeating.
· With
“0”
specified, the test infinitely runs until it is forcibly terminated with
<term>
command
or until an error is detected.
(4) Enter
<exec>
command on the command line of the
System Diagnostics
screen.
The following is an example of specified command.
·
<exec>
command is accepted only when the test status is
“Idle.”
· When
entering
<exec>
command, the test ending condition can be confirmed.
TeDoLi> option
Execution Control:
Loop continuously.
TeDoLi> time 15
TeDoLi> option
Execution Control:
Execution Time Limit: 15 minutes.
TeDoLi> round 100
TeDoLi> option
Execution Control:
Round times: 100 rounds.
TeDoLi> exec
Executing the test.
Execution Control:
Loop continuously.
Summary of Contents for Express 5800
Page 73: ...73 Memo ...
Page 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Page 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Page 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Page 573: ...573 Memo ...
Page 583: ...Software 583 Memo ...
Page 690: ...Operation and Maintenance 690 Memo ...
Page 719: ...XXIX Memo ...