Operation and Maintenance
646
14. Check results of executed test.
Enter
<fail>
command in the command line of the
System Diagnostics
screen to check the
executed results of the test.
Nothing is displayed when there is no error.
When an error occurs, detailed information is displayed of all the test result with error.
The following is an example of screen when an error occurs.
When an error occurs, replace the target parts and execute the diagnostics test again.
15. Eject the media from the DVD drive.
TeDoLi> fail
----------------------
BM/MB/PCI8/Port1(eth0)
----------------------
Device number : 16
Terminated the test due to an unexpected error.
Set loopback mode error.
Ether operation error occurred.
API status : 00 (H)
Driver status : 5f (H)
Set loopback mode is not completed.
Controller registers :
000c0241 00080380 04008002 00001000
00000000 000000fe 00000000 310000f8
00001000 00000000 00000000 00000008
00000004 00000000 00000000 00000000