Operation and Maintenance
666
MT Test
(1) Outline
MT reading test
This test starts reading from the top block on a magnetic media and checks if the data is
properly transmitted.
When the blocks are read once, the test round counts up one.
Test ends after the test is executed for ten rounds.
(Note)
Before the test for assembled type MT device is executed, move the media from the
magazine to the drive since it is not allowed moving the drive from the magazine. If the
media is not moved, the error as below will occur.
Check condition Key:2, ASC:3a, ASCQ:00 Medium not present
Using a medium with no data written ends the test abnormally (fail).
Check condition key:8, ASC:14, ASCQ:03 End-of-data not found
When using a new medium for the test, create the test medium with command such as dd
command.
(Example: dd if=xxxxxx of=xxxxxx bs=512)
(2) Message
1. Standard
message
Message Content
Device information is as follows.
Vendor name : xx
Product name : xx
Firmware rev. : xx
Channel :
xx
SCSI ID
: xx
LUN :
xx
Vender name of device, product name, FW revision
and others are displayed.
MT read test start.
MT reading test is started.
Block size
: xx
Transfer block : xx
Read buffer
: xx
Test information is displayed.
Test is finished normally.
Test ended normally.
Summary of Contents for Express 5800
Page 73: ...73 Memo ...
Page 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Page 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Page 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Page 573: ...573 Memo ...
Page 583: ...Software 583 Memo ...
Page 690: ...Operation and Maintenance 690 Memo ...
Page 719: ...XXIX Memo ...