4-30 Configuring Your Server
1.
See the section "Preparing for Installation and Removal" as described in Chapter 9 of this
guide to prepare.
2.
Remove the logic cover (see Chapter 9).
3.
Remove the riser card (see Chapter 9).
4.
Locate the position of the RAID configuration jumper on the mother board as shown
below.
5.
Remove the jumper from position 2 – 3 on jumper block.
6.
Reinstall the jumper on position 1 – 2 on jumper block.
7.
Reinstall the server removed in Step 2.
8.
Plug the power cord to your server and turn on the server.
9.
Run the BIOS SETUP utility described earlier in the chapter.
10.
Choose the Peripheral Configuration submenu in the Advanced menu.
11.
Change the options as follows.
SATA Controller Mode Option: Enhanced
SATA RAID: Enabled
12.
Save and exit the BIOS SETUP utility
REAR
RAID configuration jumper
FRONT
RAID
disable
RAID
enable
Mother board