8-6 Troubleshooting
Error
code
Error message
Recommended Action
02D1
System Memory exceeds the CPU's caching
limit.
02F4
EISA CMOS not write able.
02F5
DMA Test Failed.
02F6
Software NMI Failed.
02F7
Fail-safe Timer NMI Failed.
Contact your service representative.
0B22
Processors are installed out of order.
Request the maintenance to replace the CPU.
0B28
Unsupported Processor detected on
Processor 1.
0B29
Unsupported Processor detected on
Processor 2.
Make sure that the server supports the CPU.
If you are not sure, contact your service
representative to request the maintenance.
0B30
FAN1 Alarm occurred.
0B31
FAN2 Alarm occurred.
0B32
FAN3 Alarm occurred.
0B33
FAN4 Alarm occurred.
0B34
FAN5 Alarm occurred.
0B35
FAN6 Alarm occurred.
0B36
FAN7 Alarm occurred.
0B37
FAN8 Alarm occurred.
Contact your service representative to replace
the fan.
0B5F
Forced to use Processor with error
Because an error is detected in every CPU,
the system is forcibly started. Contact your
service representative.
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
Contact your service representative.
0B70
The error occurred during temperature
sensor reading.
Contact your service representative.
0B71
System Temperature out of the range.
Contact your service representative to replace
the fan.
0B74
The error occurred during voltage sensor
reading.
0B75
System voltage out of the range.
Contact your service representative.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core Hardware failure.
0B83
BMC 1BF or 0BF check failed.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
Summary of Contents for Express5800/120Rh-2
Page 142: ...4 46 Configuring Your Server This page is intentionally left blank ...
Page 236: ...7 12 Maintenance This page is intentionally left blank ...
Page 320: ...9 46 Upgrading Your Server Pin Red Pin Red N8103 80F N8103 81F ...
Page 336: ...9 62 Upgrading Your Server This page is intentionally left blank ...
Page 338: ...A 2 Specifications This page is intentionally left blank ...
Page 346: ...C 2 IRQ This page is intentionally left blank ...
Page 406: ...G 4 Product Configuration Record Table This page is intentionally left blank ...