Troubleshooting 8-7
Error
code
Error message
Recommended Action
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0B92
Internal Use Area of BMC FRU corrupted.
This is not a fatal error. Turn off the power
once and then on again to restart the server.
If the error cannot be corrected, contact your
service representative.
0B93
BMC SDR Repository empty.
Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service representative.
0B94
IPMB signal lines do not respond.
This is not a fatal error. Turn off the power
once and then on again to restart the server.
If the error cannot be corrected, contact your
service representative.
0B95
BMC FRU device failure.
This is not a fatal error. Turn off the power
once and then on again to restart the server.
If the error cannot be corrected, contact your
service representative.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0B9A
Management controller not responding.
Update the RMC firmware. If the error cannot
be corrected, contact your service
representative.
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0BB0
SMBIOS – SROM data read error.
0BB1
SMBIOS – SROM data checksum bad.
Contact your service representative.
8100
Memory Error detected in DIMM group #1.
8101
Memory Error detected in DIMM group #2.
8102
Memory Error detected in DIMM group #3.
Contact your service representative to replace
the DIMM in the relevant group.
None
Expansion ROM not initialized – PCI Mass
Storage Controller in slot n (n: slot number)
Disable initialization of the optional device
expansion ROM by using the BIOS SETUP
utility (see Chapter 4).
H/W Configuration of BMC is corrupted.
!! Update BMC F/W Configuration by
configuration tool !!
!! Refer to BMC configuration manual !!
Use the NEC EXPRESSBUILDER to
configure the remote management card (see
Chapter 6).
Summary of Contents for Express5800/120Rh-2
Page 142: ...4 46 Configuring Your Server This page is intentionally left blank ...
Page 236: ...7 12 Maintenance This page is intentionally left blank ...
Page 320: ...9 46 Upgrading Your Server Pin Red Pin Red N8103 80F N8103 81F ...
Page 336: ...9 62 Upgrading Your Server This page is intentionally left blank ...
Page 338: ...A 2 Specifications This page is intentionally left blank ...
Page 346: ...C 2 IRQ This page is intentionally left blank ...
Page 406: ...G 4 Product Configuration Record Table This page is intentionally left blank ...