5-16
Problem Solving
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B46
ESMINT not
configured
Interrupt request for PCI board
and ESM are incorrect.
Start the SETUP utility, and specify the
correct value for [System Hardware]
→
[ESM IRQ] and [Advanced]
→
[PCI Device]
→
[PCI IRQ], then restart the server.
If the error persists, contact your service
representative to replace the I/O riser board
or system I/O board.
0B50
CPU #1 with error
taken off line.
Because an error was detected in
CPU #1, it was degraded.
0B51
CPU #2 with error
taken off line.
Because an error was detected in
CPU #2, it was degraded.
0B52
CPU #3 with error
taken off line.
Because an error was detected in
CPU #3, it was degraded.
0B53
CPU #4 with error
taken off line.
Because an error was detected in
CPU #4, it was degraded.
The displayed CPU is degraded. Contact
your service representative to replace the
failed CPU.
0B5F
Forced to use CPU
with error
CPU error is detected.
The system is started forcibly because
errors are detected on all CPUs. Contact
your service representative to replace the
CPU.
0B60
DIMM group #1 has
been disabled
A memory error was detected in
memory DIMM group #1. Memory
DIMM group #1 is degraded.
0B61
DIMM group #2 has
been disabled
A memory error was detected in
memory DIMM group #2. Memory
DIMM group #2 is degraded.
0B62
DIMM group #3 has
been disabled
A memory error was detected in
memory DIMM group #3. Memory
DIMM group #3 is degraded.
0B63
DIMM group #4 has
been disabled
A memory error was detected in
memory DIMM group #4. Memory
DIMM group #4 is degraded.
Contact your service representative to
replace the DIMM board.
0B6F
DIMM group with
error is enabled
Memory error was detected.
The system is forcibly started because
errors are detected in all memory devices.
Contact your service representative to
replace the DIMM boards.
0B70
The error occurred
during temperature
sensor reading
An error was detected in the
middle of detection of abnormal
temperature.
0B71
System Temperature
out of the range
Abnormal temperature was
detected.
0B74
The error occurred
during voltage
sensor reading
An error occurred during detection
of voltage.
0B75
System Voltage out
of the range
Abnormal system voltage was
detected.
0B78
The error occurred
during fan sensor
reading
An error was detected during read
of FAN sensor.
Contact your service representative to
replace the I/O riser board, or system I/O
board or baseboard.
Summary of Contents for Express5800/140Hb
Page 1: ... S e r v i c e G u i d e EXPRESS5800 140Hb ...
Page 2: ......
Page 3: ... S e r v i c e G u i d e EXPRESS5800 140Hb ...
Page 10: ...viii Contents ...
Page 18: ...xvi Using This Guide ...
Page 48: ...1 30 System Overview ...
Page 64: ...2 16 Setting Up the System Figure 2 10 Connecting the AC Power Cord to the Server ...
Page 98: ...3 28 Configuring Your System ...
Page 101: ......
Page 176: ...4 76 Disassembly and Reassembly ...
Page 200: ...5 24 Problem Solving ...
Page 201: ...6 Illustrated Parts Breakdown Exploded View Field Replaceable Units ...
Page 211: ...A Technical Specifications Server Unit ...
Page 214: ...A 4 Technical Specifications ...
Page 220: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Page 231: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Page 234: ...D 4 ROMPilot BIOS Error Codes ...
Page 235: ...E Connectors Overview External Device Connector Pin Information ...
Page 250: ...10 Glossary ...
Page 256: ...Index 4 ...
Page 257: ...xx ...
Page 258: ... 456 01547 000 ...