Problem Solving 5-17
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B7C
The error occurred
during the redundant
power module
confirmation
An error occurred while redundant
power supply was configured.
Contact your service representative to
replace the power unit.
0B7D
The normal
operation can not be
guaranteed with use
of only one PSU.
System is running on only one
power supply.
Contact your service representative to
replace the power unit.
0B80
BMC Memory Test
Failed.
BMC SRAM test error
0B81
BMC Firmware Code
Area CRC check
failed.
CRC error occurred in BMC code
area.
0B82
BMC core hardware
failure.
A firmware task cannot be ready
due to BMC hardware error.
0B90
BMC Platform
Information Area
Corrupted.
The platform information area of
BMC is damaged.
0B93
BMC SDR
Repository empty.
No BMC SDR data exists.
Contact your service representative to
replace the I/O riser board.
0B95
BMC FRU device
failure.
Access to SROM that contains the
chassis information failed.
Contact your service representative to
replace the baseboard.
0B96
BMC SDR
Repository failure.
Access to FMEM sector that
contains SDR information failed.
Contact your service representative to
replace the riser card.
0BB0
SMBIOS - SROM
data read error
Read error of SROM data
0BB1
SMBIOS - SROM
data checksum bad
Checksum for the SROM data is
incorrect.
Contact your service representative.
0BC0
POST detected
startup failure of
CPU #1.
CPU #1 failed to startup.
0BC1
POST detected
startup failure of
CPU #2.
CPU #2 failed to startup.
0BC2
POST detected
startup failure of
CPU #3.
CPU #3 failed to startup.
0BC3
POST detected
startup failure of
CPU #4.
CPU #4 failed to startup.
Contact your service representative to
replace the failed CPU.
Summary of Contents for Express5800/140Hb
Page 1: ... S e r v i c e G u i d e EXPRESS5800 140Hb ...
Page 2: ......
Page 3: ... S e r v i c e G u i d e EXPRESS5800 140Hb ...
Page 10: ...viii Contents ...
Page 18: ...xvi Using This Guide ...
Page 48: ...1 30 System Overview ...
Page 64: ...2 16 Setting Up the System Figure 2 10 Connecting the AC Power Cord to the Server ...
Page 98: ...3 28 Configuring Your System ...
Page 101: ......
Page 176: ...4 76 Disassembly and Reassembly ...
Page 200: ...5 24 Problem Solving ...
Page 201: ...6 Illustrated Parts Breakdown Exploded View Field Replaceable Units ...
Page 211: ...A Technical Specifications Server Unit ...
Page 214: ...A 4 Technical Specifications ...
Page 220: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Page 231: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Page 234: ...D 4 ROMPilot BIOS Error Codes ...
Page 235: ...E Connectors Overview External Device Connector Pin Information ...
Page 250: ...10 Glossary ...
Page 256: ...Index 4 ...
Page 257: ...xx ...
Page 258: ... 456 01547 000 ...