G-20
4.
Locate the slide rail assembly on the right side of the rack frame at the position defined by the template.
Stamp (located at the upper right
position of slide rail assembly)
Slide rail assembly
Stamp (located at the lower
right position of slide rail
assembly)
IMPORTANT:
Check that the slide rail assembly is installed as follows:
The bracket face of the slide rail assembly is directed to the outside of the
rack.
The end with the slide bracket is directed to the rear of the rack.
Angle holes for screw settings are provided on the front and rear frames of the rack. Some
NEC racks have frames with round marks by 1U. As shown in the figure below, place the
slide rail assembly so that one of the round marks is located at the upper right of the top
screw hole of the slide rail assembly.