105
-
4.10.7
Replacement of SCSI-BP (5HDD/3HDD) on 140Rd-4
Chassis
Notes:
To replace the SCSI-BP, first remove all the HDDs from the Server.
Before the replacement, always back up the RAID configuration information.
After the replacement of the SCSI-BP, insert the HDDs into the original slots without changing the
installation positions.
Before removing the HDDs, note their installation positions and put labels indicating the
installation positions on the HDDs.
Before the SCSI-BP can be replaced, the HDD cage must be removed.
1.
Make sure that the power of the Server is off, and disconnect the AC cables from all the
power units.
2.
Remove all HDDs, CD-ROM module and front panel module from the Server.
Remove any backup devices if installed.
3.
Remove the rear access and front access covers.
4.
For the Server of the 3.5-inch device model (3HDD model), pull out the SCSI and power
cables for 3.5-inch devices from the HDD cage.
5.
Remove the HDD cage fixing screws (2) on the front of the Server.
HDD cage
Summary of Contents for EXPRESS5800/140He
Page 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Page 153: ... 137 voltage drop and the system is restarted This is not an error ...
Page 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Page 163: ... 147 ...
Page 181: ... 165 12 3 Block Diagram ...
Page 182: ... 166 This page is intentionally left blank ...
Page 183: ... 167 This page is intentionally left blank ...
Page 184: ... 168 ...