130
-
On-screen message
Action
0280
Previous boot incomplete - Default
configuration used
The system will start with "Uncached" state.
Start BIOS SETUP to reconfigure the
system.
02B0
Diskette drive A error
Check the FDD cable connection.
Replace the FDD.
Replace the FDD cable.
Replace the CD/FD board.
02B1
Diskette drive B error
Check the settings of BIOS SETUP.
Replace the I/O board.
02B2
Incorrect drive A type – run SETUP
Start SETUP to check if [Floppy Options] -
[Diskette A:] is set to [1.44/1.25Mb 3 1/2"].
Replace the FDD.
02B3
Incorrect drive B type – run SETUP
Check the settings of BIOS SETUP.
Replace the I/O board.
02D0
System cache error –Cache disabled
Replace the processor.
Replace the processor board.
02D1 System
Memory
exceeds the CPU's
caching limit
Replace the processor.
Replace the processor board.
02F5
DMA test failed
02F6
Software NMI Failed
02F7
Fail-safe Timer NMI Failed
Replace the I/O board.
0500
Expansion ROM not initialized PCI Slot
01
0501
Expansion ROM not initialized PCI Slot
02
0502
Expansion ROM not initialized PCI Slot
03
0503
Expansion ROM not initialized PCI Slot
04
0504
Expansion ROM not initialized PCI Slot
05
0505
Expansion ROM not initialized PCI Slot
06
0506
Expansion ROM not initialized PCI Slot
07
0507
Expansion ROM not initialized PCI Slot
08
Set [Option ROM] for the PCI slot to which
the boot device is connected to "Enabled",
and "Disabled" for other slots.
Replace the PCI board.
Replace the I/O board.
0611 IDE
configuration
Changed
0613
COM A configuration changed
0614
COM A config. Error - device disabled
0615
COM B configuration changed
0616
COM B config. Error - device disabled
0617
Floppy configuration changed
0618
Floppy config. Error - device disabled
0619
Parallel port Configuration changed
061A
Parallel port config.
Error - device disabled
Replace the I/O board.
Replace the connected devices.
Summary of Contents for EXPRESS5800/140He
Page 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Page 153: ... 137 voltage drop and the system is restarted This is not an error ...
Page 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Page 163: ... 147 ...
Page 181: ... 165 12 3 Block Diagram ...
Page 182: ... 166 This page is intentionally left blank ...
Page 183: ... 167 This page is intentionally left blank ...
Page 184: ... 168 ...