131
-
On-screen message
Action
0B00
Rebooted during BIOS boot at post
Code
Replace the I/O board.
0B1B
PCI System Error on
Bus/Device/Function
0B1C
PCI Parity Error on
BUS/Device/Function
Replace the I/O board.
Replace the PCI board.
0B22
Processors are installed out of order.
0B28
Unsupported CPU detect on CPU
Slot1
0B29
Unsupported CPU detect on CPU
Slot2
0B2A
Unsupported CPU detect on CPU
Slot3
0B2B
Unsupported CPU detect on CPU
Slot4
Replace the processor.
0B30
Fan 1 Alarm occurred.
0B31
Fan 2 Alarm occurred.
0B32
Fan 3 Alarm occurred.
0B33
Fan 4 Alarm occurred.
0B34
Fan 5 Alarm occurred.
0B35
Fan 6 Alarm occurred.
0B36
Fan 7 Alarm occurred.
0B37
Fan 8 Alarm occurred.
Clean the fan.
Replace the fan.
0B50
Processor#1 with error taken off line.
0B51
Processor#2 with error taken off line.
0B52
Processor#3 with error taken off line.
0B53
Processor#4 with error taken off line.
0B5F
Forced to use CPU with error.
Replace the processor.
Replace the processor board.
After replacement, start SETUP and
execute [Clear CPU Error].
Update the system with the latest BIOS.
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4has been disabled
0B64
DIMM group #5 has been disabled
0B65
DIMM group #6 has been disabled
0B66
DIMM group #7 has been disabled
0B67
DIMM group #8 has been
disabled
Insert the DIMM again.
Check if ECC 1-bit/multi-bit error is
recorded in the system event log. If the
error is recorded, replace the relevant
DIMMs in pair.
If the failed DIMMs cannot be identified,
replace all the DIMMs in the relevant group.
Replace the memory board.
After the replacement, start SETUP and
execute [Clear DIMM Error].
0B70
The error occurred during temperature
sensor reading
Replace the front panel.
Replace the CPU.
Replace the Processor board.
Replace the I/O board.
0B71
System Temperature out of the range
Set the room temperature in the range
between 10 to 35ºC.
Check the system event log to identify the
thermal sensor which has detected the
out-of-range temperature.
Summary of Contents for EXPRESS5800/140He
Page 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Page 153: ... 137 voltage drop and the system is restarted This is not an error ...
Page 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Page 163: ... 147 ...
Page 181: ... 165 12 3 Block Diagram ...
Page 182: ... 166 This page is intentionally left blank ...
Page 183: ... 167 This page is intentionally left blank ...
Page 184: ... 168 ...