133
-
On-screen message
Action
0BC0
POST detected startup failure of
CPU#1
0BC1
POST detected startup failure of
CPU#2
0BC2
POST detected startup failure of
CPU#3
0BC3
POST detected startup failure of
CPU#4
Check the CPU installation.
Replace the CPU.
Replace the processor board.
Replace the I/O board.
After replacement, start SETUP and
execute [Processor Retest].
0BD0
1st SMBus address not acknowledged.
0BD1
1st SMBus device Error detected.
0BD2
1st SMBus timeout.
Replace the I/O board.
Replace the PCI Option card.
0BD3
2nd SMBus address not
acknowledged.
0BD4
2nd SMBus device Error detected.
0BD5
2nd SMBus timeout.
Replace the processor board.
Replace the I/O board.
Replace the memory board.
Replace the DIMM.
0BD6
3rd SMBus address not acknowledged.
0BD7
3rd SMBus device Error detected.
0BD8
3rd SMBus timeout.
Check the power supply unit connection or
replace the power supply unit.
Replace the Power-BP.
Replace the I/O board.
0BD9
4th SMBus address not acknowledged.
0BDA
4th SMBus device Error detected.
0BDB
4th SMBus timeout.
Replace the processor.
Replace the processor board.
Replace the I/O board.
0BDC
5th SMBus address not acknowledged.
0BDD
5th SMBus device Error detected.
0BDE
5th SMBus timeout.
Replace the front panel.
Replace the SCSI-BP.
Replace the I/O board.
0BE8
IPMB address not acknowledged
0BE9
IPMB device error detected
0BEA IPMB
timeout
Replace the front panel.
Replace the SCSI-BP.
Replace the I/O board.
8120
Unsupported DIMM detected in DIMM
group #1
8121
Unsupported DIMM detected in DIMM
group #2
8122
Unsupported DIMM detected in DIMM
group #3
8123
Unsupported DIMM detected in DIMM
group #4
8124
Unsupported DIMM detected in DIMM
group #5
8125
Unsupported DIMM detected in DIMM
group #6
Replace the DIMMs in relevant group.
8126
Unsupported DIMM detected in DIMM
group #7
8127
Unsupported DIMM detected in DIMM
group #8
Replace the DIMMs in relevant group.
8130
Mismatch DIMM detected in DIMM
group #1
8131
Mismatch DIMM detected in DIMM
group #2
Use the same type of DIMMs in the relevant
group.
Summary of Contents for EXPRESS5800/140He
Page 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Page 153: ... 137 voltage drop and the system is restarted This is not an error ...
Page 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Page 163: ... 147 ...
Page 181: ... 165 12 3 Block Diagram ...
Page 182: ... 166 This page is intentionally left blank ...
Page 183: ... 167 This page is intentionally left blank ...
Page 184: ... 168 ...