140
-
8.6 Error Messages in Remote Management
While the remote management is used, error messages may appear on the management PC at the
occurrence of an error. This section lists the error messages and the actions taken against the
errors.
[Fatal error]
No. Error
message
Action
1
Fatal error. JavaVM is
terminated.
Login to the system again. If the same message
appears again, set up the system again. If the same
message reappears, replace the I/O Board.
2
A fatal software error
occurred.
Login to the system again. If the same message
appears again, set up the system again. If the same
message reappears, replace the I/O Board.
[Error at login]
No. Error
message
Action
1
Authentication error
Check the user name and password. Then reenter
them again.
[Access authority error]
No. Error
message
Action
1
The operation is not
permitted. The authority level
is not enough.
Perform the operation in the administrator level.
Contact your administrator.
[Network errors]
No. Error
message
Action
1
HTTP communication failed.
After checking the network environment, retry the
operation. If the operation fails several times, replace
the Management LAN Card. If the error still occurs,
replace the I/O Board.
2
The IP address could not be
solved.
3
The operation cannot reach
the target host.
Check the network environment. The Remote KVM
Console is not available in the connection through a
proxy.
4
A network error occurred.
After checking the network environment, retry the
operation. If the operation fails several times, replace
the Management LAN Card. If the error still occurs,
replace the I/O Board.
5
The applet is downloaded
unsuccessfully.
After checking the network environment, retry the
operation. If the operation fails several times, replace
the Management LAN Card. If the error still occurs,
replace the I/O Board. If the SSL is made effective,
only a single client can connect to the unit at a time.
Retry the operation after terminating the operation of
another client.
Summary of Contents for EXPRESS5800/140He
Page 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Page 153: ... 137 voltage drop and the system is restarted This is not an error ...
Page 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Page 163: ... 147 ...
Page 181: ... 165 12 3 Block Diagram ...
Page 182: ... 166 This page is intentionally left blank ...
Page 183: ... 167 This page is intentionally left blank ...
Page 184: ... 168 ...