General Description 2-17
Others
Memory capacity displayed on the OS = total capacity of physically installed memory –
capacity for standby memory
Memory mirroring feature: 1/2 of actually installed memory capacity
Memory RAID feature: 3/4 of actually installed memory capacity
Enabling the memory mirroring or memory RAID feature does not influence the
operations of applications.
The each feature is automatically disabled when an error message is displayed:
The following indicates that the memory mirroring /memory RAID feature has worked:
a) The Redundancy lamp on the front panel of the server lights green.
b) The failing DIMM group is degraded when the server restarts.
c) If NEC ESMPRO Agent has been installed, the following log is registered as a system
log of Event Viewer:
Source name:
ESMCommonService
Event ID:
2313
Explanation:
Part of the DIMM was isolated due to a memory error.
Memory number: XX
Date/time:
XX
d) If report setting is made through NEC ESMPRO Agent, Manager reporting and
ALIVE reporting is performed. The report contents are as follows:
Explanation:
Part of the DIMM was isolated due to a memory error.
Memory number: XX
Date/time:
XX
Summary of Contents for Express5800/140Re-4
Page 7: ......
Page 8: ......
Page 9: ......
Page 38: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Page 76: ...2 38 General Description This page is intentionally left blank ...
Page 187: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed ...
Page 494: ...F 4 Product Configuration Record Table This page is intentionally left blank ...